|T000061, K12 Tracer
Compound Image

T000061

K12 Tracer


  • Properties

    Store at:

    -80 °C

    Absorption:

    450 nm

    Emission:

    590 nm
  • References

    Contributing Lab:

    Promega Corp., Madison

    Vendor:

  • Experimental

    Assay window 4.2
    \(Z'\) 0.82
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    105 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    \(\mathrm{EC}_{50}\):

    584 nM
    displacement curve
    raw data

    Comment: CDK1-NLuc + CycB1

    Reference: source

    Assay window 3.7
    \(Z'\) 0.81
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    157 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    \(\mathrm{EC}_{50}\):

    177 nM
    displacement curve
    raw data

    Comment: CDK1-NLuc + CycE1

    Reference: source

    Assay window 3.92
    \(Z'\) 0.75
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    212 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    SNS-032

    \(\mathrm{EC}_{50}\):

    989 nM
    displacement curve
    raw data

    Comment: CDK10-NLuc + CycL2

    Reference: source

    Assay window 4.07
    \(Z'\) 0.9
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    217 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    165 nM
    displacement curve
    raw data

    Comment: CDK11A-NLuc + CycK

    Reference: source

    Assay window 4.66
    \(Z'\) 0.88
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    137 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    278 nM
    displacement curve
    raw data

    Comment: CDK11B-NLuc + CycL2

    Reference: source

    Assay window 5.22
    \(Z'\) 0.64
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    92 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    306 nM
    displacement curve
    raw data

    Comment: CDK14-NLuc + CycY

    Reference: source

    Assay window 3.9
    \(Z'\) 0.71
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    40 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    185 nM
    displacement curve
    raw data

    Comment: NLuc-CDK15 + CycY

    Reference: source

    Assay window 4.11
    \(Z'\) 0.71
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    146 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    42 nM
    displacement curve
    raw data

    Comment: CDK16-NLuc + CycY

    Reference: source

    Assay window 4.26
    \(Z'\) 0.74
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    121 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    51 nM
    displacement curve
    raw data

    Comment: CDK17-NLuc + CycY

    Reference: source

    Assay window 7.53
    \(Z'\) 0.76
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    126 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    467 nM
    displacement curve
    raw data

    Comment: CDK18-NLuc + CycY

    Reference: source

    Assay window 4.64
    \(Z'\) 0.86
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    164 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AT7519

    \(\mathrm{EC}_{50}\):

    2 µM
    displacement curve
    raw data

    Comment: CDK3-NLuc + CycE1

    Reference: source

    Assay window 3.75
    \(Z'\) 0.9
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    127 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Palbociclib

    \(\mathrm{EC}_{50}\):

    33 nM
    displacement curve
    raw data

    Comment: NLuc-CDK4 + CycD1

    Reference: source

    Assay window 5.16
    \(Z'\) 0.77
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    88 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Abemaciclib

    \(\mathrm{EC}_{50}\):

    2 nM
    displacement curve
    raw data

    Comment: NLuc-CDK4 + CycD3

    Reference: source

    Assay window 3.53
    \(Z'\) 0.82
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    77 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    \(\mathrm{EC}_{50}\):

    734 nM
    displacement curve
    raw data

    Comment: NLuc-CDK7 + pGEM

    Reference: source

    Assay window 11.59
    \(Z'\) 0.93
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    13 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    \(\mathrm{EC}_{50}\):

    11 nM
    displacement curve
    raw data

    Comment: NLuc-CDK9 + CycK

    Reference: source